LAMP IFP 800 LABEL OKP 6375600071 Lamp IFP 800 pulse with direct glow body and with foil current input is designed for optical pumping of active elements of lasers, is supplied for the needs of the national economy and for export. General view of the overall, mounting and connecting dimensions of the lamp are given below. BASIC ELECTRICAL PARAMETERS AND RADIATION PARAMETERS Parameter name Norm when receiving and delivering during the operating time Note Ignition voltage, V, not more than mode A, B, V 700 900 Self-breakdown voltage, at least mode A, B, V 2500 - Illumination in the direction perpendicular to the lamp axis, cd, not less than mode A, B 2500 1800 * Mode V 1400 1100 * Note The indicated values of lighting are provided when the lamp is switched on with the allowable electrical energy of the discharge and the duration of the light pulse indicated in the table of permissible operating conditions. ALLOWABLE OPERATING MODES Parameter name Norm Comment Permissible electric energy of the discharge, J, not more than mode A, B 800 mode V 400 The lamp switching circuit (recommended) is shown below. C1 Storage Capacitor 600+-60 uF (Mode A) C2 Blocking Capacitor 0.1-0.5 uF G Power supply Provides charge of storage capacitor C1 up to 1600 V discharge (mode A) at charge-discharge cycles frequency 0.1 Hz pause of charging current after next radiation pulse not less than 50-600 ms GT Control unit Provides a surge of synchronous pulses G and GG with the frequency specified in the table of permissible operating modes GG Ignition device Provides the supply of ignition pulses with the parameters specified in the table of permissible operating modes L Inductance It is selected from the condition for the length of the pulse of light intensity 600 + -50 µs V Lamp IFP 800 Note: The active resistance of the distributed circuit, measured at a constant current, is no more than 0.05 Ohm. Parameter name Norm Remark Permissible operating voltage, V mode A, B 1440-1760 mode V 1260-1540 Capacitance capacitor capacity, µF mode A, B 540-660 mode V 360-440 Duration of light pulse at 0.35, µs mode A, B, V 550-650 Pulse repetition frequency, Hz not more than mode A 1/15 mode B 1 mode V 10 The parameters of the ignition pulses are ignition-sequential; peak ignition voltage, kV, measured at 100 kO load Mode A, B, V 16-24 Duration of the largest half-wave of the ignition pulse at 0.1 µs mode A, B, V 1-5 Ignition pulse duration at 0.1 µs, mode A, B, V 10 The number of half-full of the ignition pulse with an amplitude of not less than 0.5 st of the maximum, not less than Mode A, B, V 3 The time delay of applying voltage to the main electrodes of the lamp after the next discharge, ms, at least mode A, B, V 50-600 Notes: 1 In mode A, the lamp cooling is natural. 2 In modes B, V, the lamp cooling is water, on the length of the discharge part of the lamp and the edges. Precious metals are not contained. The lamp operating time is 30000 (mode A), 5000 (mode B), 50000 (mode V) pulses. OPERATING INSTRUCTIONS 1. The lamp can work in any position. 2. Before installation in the equipment, the lamp should be wiped with cotton wool soaked with rectified alcohol. 3. During operation, the lamp should be covered with a protective cover protecting from splinters in the event of a lamp explosion. 4. The lamp in modes B, V works with water cooling at the bottom of the discharge part of the lamp and the lances. The water flow rate is 5-8 l / min with an internal diameter of the cooling system of 20 mm. The water temperature on the course must not exceed 20 ° C. 5. In mode V, the lamp works in series. The duration of continuous work in the series is3 minutes, the interval between the series is 20 minutes. 6. In mode A, lamp cooling is natural MANUFACTURER'S GUARANTEE The manufacturer guarantees that the lamp meets the requirements of the technical conditions for 4 years of its storage, including operating time if the consumer observes the conditions and rules for storage, transportation, installation and operation established in the technical conditions. Lamps are made in the climatic version of the UKHL accommodation category. 4.2 GOST 15150-69. Technical conditions of ODL. 337.072 TU. Date of manufacture Place for stamp OTK Place for stamp State Acceptance